{"id":25499,"date":"2021-06-15T15:44:45","date_gmt":"2021-06-15T14:44:45","guid":{"rendered":"https:\/\/www.hydro-x.co.uk\/hx-training\/?p=25499"},"modified":"2022-02-14T10:47:53","modified_gmt":"2022-02-14T10:47:53","slug":"how-to-check-fire-doors","status":"publish","type":"post","link":"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/","title":{"rendered":"How to check fire doors?"},"content":{"rendered":"[vc_row][vc_column][vc_column_text]\n<h1><strong>How to check fire doors?<\/strong><\/h1>\n<p>Reading Time &#8211; Approx. 3.5 Mins[\/vc_column_text][vc_column_text]\n<h2><b>What is a fire door?<\/b><\/h2>\n<p><span style=\"font-weight: 400; font-size: 18px;\">A fire door provides not just a means of escape from a fire within a building, such as an office, but acts as a barrier against fire from spreading from one room to another protecting the contents and the rest of the building as well as nearby buildings.<\/span><\/p>\n<p><span style=\"font-weight: 400; font-size: 18px;\">A properly fitted and maintained fire door can stop and prevent fire and smoke from spreading, by containing it within a fire compartment for 30 minutes, and in some cases up to an hour. They are an integral part of any building&#8217;s passive fire safety plan.<\/span><\/p>\n<p><span style=\"font-weight: 400; font-size: 18px;\">As part of a fire safety plan, doors should be signed and marked whether:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400; font-size: 18px;\" aria-level=\"1\"><span style=\"font-weight: 400;\">It should be kept closed when it is not in use<\/span><\/li>\n<li style=\"font-weight: 400; font-size: 18px;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Should be kept locked when not in use<\/span><\/li>\n<li style=\"font-weight: 400; font-size: 18px;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Are to be held open using an automatic release mechanism<\/span><\/li>\n<\/ul>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_btn title=&#8221;Book a Fire Door Inspection Course&#8221; shape=&#8221;rounded&#8221; color=&#8221;warning&#8221; size=&#8221;xl&#8221; align=&#8221;center&#8221; link=&#8221;url:https%3A%2F%2Fwww.hydro-x.co.uk%2Fhx-training%2Ffire-door-inspection%2F|title:Fire%20Door%20Inspection%20course|target:_blank&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]\n<h3><b>What is a fire door composed of?<\/b><\/h3>\n<p><span style=\"font-weight: 400; font-size: 18px;\">As a fire door is a specially engineered safety device it is composed differently from a standard door. Most fire doors are thicker than a standard door with most having a solid core (some manufacturers do produce hollow core doors).<\/span><\/p>\n<p><span style=\"font-weight: 400; font-size: 18px;\">In every groove of the door, intumescent seals are fitted, which when exposed to the heat of a fire, expands and seals the gap between the door and frame.<\/span>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]\n<h3><b>How Long Do Fire Doors Last?<\/b><\/h3>\n<p><span style=\"font-weight: 400; font-size: 18px;\">Fire doors are normally tested to last to hold fire back in a fire compartment for 30 minutes or 60 minutes, provided they are installed correctly. The top edge of the door is usually where the certification of the fire door can be found, identifying if the door is rated FD30 (30mins) or FD60\u00a0 (60mins)<\/span><\/p>\n<p><span style=\"font-weight: 400; font-size: 18px;\">A fire door is only effective if the door is closed &#8211; and all doors should have a self-closing device, which a competent fire door inspector should check is fully functioning.<\/span><\/p>\n<p><span style=\"font-weight: 400; font-size: 18px;\">Fire doors that are subject to regular use could deteriorate over time and require regular inspections to remain both compliant and well maintained.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400; font-size: 18px;\">Hydro-x Training is the main provider of <\/span><a href=\"https:\/\/www.hydro-x.co.uk\/testarea\/fire-door-inspection\/\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400; font-size: 18px;\">Fire Door Inspection courses<\/span><\/a><span style=\"font-weight: 400; font-size: 18px;\"> in the UK and it is accredited by City and Guilds. Contact us about your <\/span><a href=\"https:\/\/www.hydro-x.co.uk\/testarea\/on-site-training\/\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400; font-size: 18px;\">On-Site<\/span><\/a><span style=\"font-weight: 400; font-size: 18px;\"> or <\/span><a href=\"https:\/\/www.hydro-x.co.uk\/testarea\/fire-door-inspection\/\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400; font-size: 18px;\">Virtual training requirements.<\/span><\/a>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;25879&#8243; img_size=&#8221;full&#8221; add_caption=&#8221;yes&#8221; alignment=&#8221;center&#8221; label=&#8221;&#8221;][vc_separator][vc_column_text]\n<h2><b>Reasons why we inspect fire doors<\/b><\/h2>\n<p><span style=\"font-weight: 400; font-size: 18px;\">As fire doors are an integral part of a fire safety plan, with their primary purpose being to save lives and offer protection to buildings and their contents they must be fitted correctly and regularly inspected for any defects and maintenance purposes.<\/span><\/p>\n<p><span style=\"font-weight: 400; font-size: 18px;\">Any slight damage or changes to the door can affect how it works or operates during a fire, with fire resistance being compromised. Fire door inspections can highlight if there are large gaps between the leaves and the frame or if the door has been correctly installed.<\/span><\/p>\n<p><span style=\"font-weight: 400; font-size: 18px;\">As inspecting fire doors is a legal requirement, using a trained and competent person is a must. This can be achieved by City and Guilds Accredited <\/span><span style=\"font-weight: 400; font-size: 18px;\">Fire Door Inspection<\/span><span style=\"font-weight: 400; font-size: 18px;\"> course by Hydro-x Training.\u00a0<\/span>[\/vc_column_text][vc_btn title=&#8221;Book a Fire Door Inspection Course&#8221; shape=&#8221;rounded&#8221; color=&#8221;warning&#8221; size=&#8221;xl&#8221; align=&#8221;center&#8221; link=&#8221;url:https%3A%2F%2Fwww.hydro-x.co.uk%2Fhx-training%2Ffire-door-inspection%2F|title:Fire%20Door%20Inspection%20course|target:_blank&#8221;][vc_column_text]\n<h3><b>Are inspections a legal requirement?<\/b><\/h3>\n<p><span style=\"font-weight: 400; font-size: 18px;\">It is a legal requirement that fire doors are routinely inspected and maintained as any change or damage that it sustains can affect its effectiveness should a fire break out.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400; font-size: 18px;\">Under <\/span><a href=\"https:\/\/www.legislation.gov.uk\/uksi\/2005\/1541\/contents\/made\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400; font-size: 18px;\">The Regulatory Reform (Fire Safety) Order 2005<\/span><\/a><span style=\"font-weight: 400; font-size: 18px;\">, it states that the Responsible Person is to make sure the fire doors and escape routes are correctly maintained and installed. <a href=\"https:\/\/www.legislation.gov.uk\/uksi\/2005\/1541\/article\/17\/made\" target=\"_blank\" rel=\"noopener\">Article 17 Fire Safety Order 2005<\/a>. The Responsible Person must employ a competent person to carry out these checks at least every 6 months, or more often in high traffic areas including hospitals and schools. Our <a href=\"https:\/\/www.hydro-x.co.uk\/testarea\/fire-door-inspection\/\" target=\"_blank\" rel=\"noopener\">Fire Door Training courses<\/a> cover all the legal requirements and correct procedures to test and maintain Fire Doors.<\/span>[\/vc_column_text][vc_column_text]\n<h3><b>An inspection should include:<\/b><\/h3>\n<p><span style=\"font-weight: 400; font-size: 18px;\">A fire door inspection should follow the recommendation set down in <a href=\"https:\/\/shop.bsigroup.com\/products\/fire-safety-in-the-design-management-and-use-of-buildings-code-of-practice\/tracked-changes\" target=\"_blank\" rel=\"noopener\">BS 9999<\/a><\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"text-align: center; border-bottom: #363636 solid 2px;\"><b>Frequency<\/b><\/td>\n<td style=\"text-align: left; border-bottom: #363636 solid 2px;\"><b>What to do<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; background-color: #e6e6e6;\"><span style=\"font-weight: 400;\">Daily<\/span><\/td>\n<td style=\"text-align: left; background-color: #e6e6e6;\"><span style=\"font-weight: 400;\">Automatic release mechanisms are \u2018test released\u2019<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">Monthly<\/span><\/td>\n<td style=\"text-align: left;\"><span style=\"font-weight: 400;\">Doors held open with automatic devices should be tested with a simulated power failure, fire detector or fire alarm activation<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; background-color: #e6e6e6;\"><span style=\"font-weight: 400;\">Three Monthly<\/span><\/td>\n<td style=\"text-align: left; background-color: #e6e6e6;\"><span style=\"font-weight: 400;\">As daily and monthly above<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">Six Monthly<\/span><\/td>\n<td style=\"text-align: left;\"><span style=\"font-weight: 400;\">Check smoke seals are undamaged and there is no structural damage to the door. Check the gaps are not too small or large for effective smoke sealing. Opening and closing devices are operating correctly.<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; background-color: #e6e6e6;\"><span style=\"font-weight: 400;\">Annually<\/span><\/td>\n<td style=\"text-align: left; background-color: #e6e6e6;\"><span style=\"font-weight: 400;\">As all the above<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n[\/vc_column_text][vc_column_text]\n<h2><b>What is a Fire Risk Assessment?\u00a0<\/b><\/h2>\n<p><span style=\"font-weight: 400; font-size: 18px;\">It is beneficently, whilst it is not a legal requirement, that Fire Door Inspectors have a working knowledge of general Fire Safety Risk Assessment.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400; font-size: 18px;\">Fire risk assessments include, under <a href=\"https:\/\/www.gov.uk\/workplace-fire-safety-your-responsibilities\/fire-risk-assessments\" target=\"_blank\" rel=\"noopener\">Government guidelines<\/a>,\u00a0 these five steps:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400; font-size: 18px;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Identifying fire hazards<\/span><\/li>\n<li style=\"font-weight: 400; font-size: 18px;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Identifying people at risk<\/span><\/li>\n<li style=\"font-weight: 400; font-size: 18px;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Evaluate, remove or reduce any risks<\/span><\/li>\n<li style=\"font-weight: 400; font-size: 18px;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Record your findings, prepare an emergency plan and provide training<\/span><\/li>\n<li style=\"font-weight: 400; font-size: 18px;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Review and update the fire risk assessment regularly<\/span><\/li>\n<\/ul>\n[\/vc_column_text][vc_column_text]\n<h2><b>Fire Door Inspection Course with HX Training\u00a0<\/b><\/h2>\n<p><span style=\"font-weight: 400; font-size:18px;\">This article has given a brief overview on fire safety and fire door safety. To get a full overview and to gain the skills to be able to inspect a fire door, Hydro-X training offers a City and Guilds Accredited training course that can be completed to suit your business &#8211; whether it&#8217;s On-Site training or Virtual training. All courses come complete with all the materials and expert knowledge from our experienced trainers.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400; font-size:18px;\">For more information, or to book one of the courses available, either visit our detailed course page at Hydro-X or contact us to speak to a member of the team.<\/span>[\/vc_column_text][vc_btn title=&#8221;Book a Fire Door Inspection Course&#8221; shape=&#8221;rounded&#8221; color=&#8221;warning&#8221; size=&#8221;xl&#8221; align=&#8221;center&#8221; link=&#8221;url:https%3A%2F%2Fwww.hydro-x.co.uk%2Fhx-training%2Ffire-door-inspection%2F|title:Fire%20Door%20Inspection%20course|target:_blank&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row]\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text] How to check fire doors? Reading Time &#8211; Approx. 3.5 Mins[\/vc_column_text][vc_column_text] What is a fire door? A fire door provides not just a means of escape from a fire within a building, such as an office, but acts as a barrier against fire from spreading from one room to another protecting the contents and [&hellip;]<\/p>\n","protected":false},"author":549,"featured_media":24503,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"featured_image_src":{"landsacpe":["https:\/\/www.hydro-x.co.uk\/testarea\/wp-content\/uploads\/2021\/04\/fire-door-1140x445.jpg",1140,445,true],"list":["https:\/\/www.hydro-x.co.uk\/testarea\/wp-content\/uploads\/2021\/04\/fire-door-463x348.jpg",463,348,true],"medium":["https:\/\/www.hydro-x.co.uk\/testarea\/wp-content\/uploads\/2021\/04\/fire-door-350x233.jpg",350,233,true],"full":["https:\/\/www.hydro-x.co.uk\/testarea\/wp-content\/uploads\/2021\/04\/fire-door.jpg",1200,800,false]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v19.2.1 (Yoast SEO v19.6.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Fire door regulations: How to check fire doors? | HX Training<\/title>\n<meta name=\"description\" content=\"Essential skills and knowledge on fire door inspection and checks. How often, the laws, different types of fire doors and their components.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to check fire doors?\" \/>\n<meta property=\"og:description\" content=\"How to check fire doors? Reading Time - Approx. 3.5 Mins What is a fire door? A fire door provides not just a means of escape from a fire within a\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/\" \/>\n<meta property=\"og:site_name\" content=\"Hydro-X Training\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Hydro-X-Water-Treatment-Ltd-268266923299845\/\" \/>\n<meta property=\"article:published_time\" content=\"2021-06-15T14:44:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-02-14T10:47:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hydro-x.co.uk\/testarea\/wp-content\/uploads\/2021\/04\/fire-door.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Helen Alty\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:creator\" content=\"@hydro_x\" \/>\n<meta name=\"twitter:site\" content=\"@hydro_x\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Helen Alty\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/\"},\"author\":{\"name\":\"Helen Alty\",\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/#\/schema\/person\/66e64762e103fb5fb64c1a1e53c6bad6\"},\"headline\":\"How to check fire doors?\",\"datePublished\":\"2021-06-15T14:44:45+00:00\",\"dateModified\":\"2022-02-14T10:47:53+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/\"},\"wordCount\":1130,\"publisher\":{\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/#organization\"},\"articleSection\":[\"Articles\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/\",\"url\":\"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/\",\"name\":\"Fire door regulations: How to check fire doors? | HX Training\",\"isPartOf\":{\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/#website\"},\"datePublished\":\"2021-06-15T14:44:45+00:00\",\"dateModified\":\"2022-02-14T10:47:53+00:00\",\"description\":\"Essential skills and knowledge on fire door inspection and checks. How often, the laws, different types of fire doors and their components.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"How to check fire doors?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/#website\",\"url\":\"https:\/\/www.hydro-x.co.uk\/testarea\/\",\"name\":\"Hydro-X Training\",\"description\":\"UK Leaders In Health | Safety | Compliance Training Courses\",\"publisher\":{\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.hydro-x.co.uk\/testarea\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/#organization\",\"name\":\"HX Training\",\"url\":\"https:\/\/www.hydro-x.co.uk\/testarea\/\",\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/2678262\/\",\"https:\/\/www.youtube.com\/channel\/UCyPYP798zrBLo7HFJO63gUg\",\"https:\/\/www.facebook.com\/Hydro-X-Water-Treatment-Ltd-268266923299845\/\",\"https:\/\/twitter.com\/hydro_x\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.hydro-x.co.uk\/testarea\/wp-content\/uploads\/2018\/10\/NEW-HX-Training-500px.png\",\"contentUrl\":\"https:\/\/www.hydro-x.co.uk\/testarea\/wp-content\/uploads\/2018\/10\/NEW-HX-Training-500px.png\",\"width\":500,\"height\":127,\"caption\":\"HX Training\"},\"image\":{\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.hydro-x.co.uk\/testarea\/#\/schema\/person\/66e64762e103fb5fb64c1a1e53c6bad6\",\"name\":\"Helen Alty\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Fire door regulations: How to check fire doors? | HX Training","description":"Essential skills and knowledge on fire door inspection and checks. How often, the laws, different types of fire doors and their components.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_GB","og_type":"article","og_title":"How to check fire doors?","og_description":"How to check fire doors? Reading Time - Approx. 3.5 Mins What is a fire door? A fire door provides not just a means of escape from a fire within a","og_url":"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/","og_site_name":"Hydro-X Training","article_publisher":"https:\/\/www.facebook.com\/Hydro-X-Water-Treatment-Ltd-268266923299845\/","article_published_time":"2021-06-15T14:44:45+00:00","article_modified_time":"2022-02-14T10:47:53+00:00","og_image":[{"width":1200,"height":800,"url":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-content\/uploads\/2021\/04\/fire-door.jpg","type":"image\/jpeg"}],"author":"Helen Alty","twitter_card":"summary","twitter_creator":"@hydro_x","twitter_site":"@hydro_x","twitter_misc":{"Written by":"Helen Alty","Estimated reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/#article","isPartOf":{"@id":"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/"},"author":{"name":"Helen Alty","@id":"https:\/\/www.hydro-x.co.uk\/testarea\/#\/schema\/person\/66e64762e103fb5fb64c1a1e53c6bad6"},"headline":"How to check fire doors?","datePublished":"2021-06-15T14:44:45+00:00","dateModified":"2022-02-14T10:47:53+00:00","mainEntityOfPage":{"@id":"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/"},"wordCount":1130,"publisher":{"@id":"https:\/\/www.hydro-x.co.uk\/testarea\/#organization"},"articleSection":["Articles"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/","url":"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/","name":"Fire door regulations: How to check fire doors? | HX Training","isPartOf":{"@id":"https:\/\/www.hydro-x.co.uk\/testarea\/#website"},"datePublished":"2021-06-15T14:44:45+00:00","dateModified":"2022-02-14T10:47:53+00:00","description":"Essential skills and knowledge on fire door inspection and checks. How often, the laws, different types of fire doors and their components.","breadcrumb":{"@id":"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.hydro-x.co.uk\/testarea\/how-to-check-fire-doors\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"How to check fire doors?"}]},{"@type":"WebSite","@id":"https:\/\/www.hydro-x.co.uk\/testarea\/#website","url":"https:\/\/www.hydro-x.co.uk\/testarea\/","name":"Hydro-X Training","description":"UK Leaders In Health | Safety | Compliance Training Courses","publisher":{"@id":"https:\/\/www.hydro-x.co.uk\/testarea\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hydro-x.co.uk\/testarea\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.hydro-x.co.uk\/testarea\/#organization","name":"HX Training","url":"https:\/\/www.hydro-x.co.uk\/testarea\/","sameAs":["https:\/\/www.linkedin.com\/company\/2678262\/","https:\/\/www.youtube.com\/channel\/UCyPYP798zrBLo7HFJO63gUg","https:\/\/www.facebook.com\/Hydro-X-Water-Treatment-Ltd-268266923299845\/","https:\/\/twitter.com\/hydro_x"],"logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.hydro-x.co.uk\/testarea\/#\/schema\/logo\/image\/","url":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-content\/uploads\/2018\/10\/NEW-HX-Training-500px.png","contentUrl":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-content\/uploads\/2018\/10\/NEW-HX-Training-500px.png","width":500,"height":127,"caption":"HX Training"},"image":{"@id":"https:\/\/www.hydro-x.co.uk\/testarea\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.hydro-x.co.uk\/testarea\/#\/schema\/person\/66e64762e103fb5fb64c1a1e53c6bad6","name":"Helen Alty"}]}},"_links":{"self":[{"href":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-json\/wp\/v2\/posts\/25499"}],"collection":[{"href":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-json\/wp\/v2\/users\/549"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-json\/wp\/v2\/comments?post=25499"}],"version-history":[{"count":25,"href":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-json\/wp\/v2\/posts\/25499\/revisions"}],"predecessor-version":[{"id":25882,"href":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-json\/wp\/v2\/posts\/25499\/revisions\/25882"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-json\/wp\/v2\/media\/24503"}],"wp:attachment":[{"href":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-json\/wp\/v2\/media?parent=25499"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-json\/wp\/v2\/categories?post=25499"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hydro-x.co.uk\/testarea\/wp-json\/wp\/v2\/tags?post=25499"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}