Legionella Testing Kits Pro

£65.00 (ex VAT)

Quantity Discount (%) Price
1 - 4 Kits £65.00
5 - 9 Kits 3.08 % £63.00
10 - 19 Kits 4.62 % £62.00
20 - 29 Kits 7.69 % £60.00
30 - 49 Kits 12.31 % £57.00
50+ Kits 26.15 % £48.00

Description

Why use Legionella Testing Kits Pro?

These new-to-market Legionella Testing Kits can provide a result in 25 minutes and accurately detect Legionella Bacteria Serogroups 1-15

Legionella Serogroups are the main cause of Legionnaires disease, with tests being able to isolate and detect Serogroup 1 with a separate test line, and serogroups being detachable on the next line, giving the user the key information to act upon

The easy-to-use Legionella Testing Kit uses lateral flow technology, and is highly sensitive, providing a detectable result at 100 CFU/L (0.1 CFU/ml) and action levels at 1000 CFU/L (1 CFU/ml) & 10000 CFU/L (10 CFU/ml).  

These Legionella testing kits are extremely reliable, harnessing the innovative filter technology from Hydrosense, it is capable of precisely detecting bacteria from a water sample. 

Perfect for testing for Legionella Bacteria in high areas, including cooling towers/evaporative systems, shower systems, water storage units, basins, spa & swimming pools and even the water from decorative fountains, giving unbeatable coverage from a single-use test.

Legionella Testing Kits Pro

Did you know we offer Legionella Awareness and Responsible Person Training?        Click here for more information

Unrivalled Speed

null
World’s fastest on-site Legionella Testing Kit, no need for long lab repost lead times with a real times result in just 25mins!

Easy to Use

null
With a simple to use lateral flow test, it can used by anyone with minimal training

VBNC Legionella

null
These on-site DIY Legionella Testing kits can detect Viable but Non-Culturable Legionella – which lab culture cannot

Precision

null
Capable of detecting with precision Legionella pneumophila Serogroups 1-15 – the groups behind 97% of Legionnaires Disease cases.

Who should use Legionella Testing Kits?

Any industry that handles water is at risk of Legionella bacteria being present and possible Legionella pneumophila infection.

For some industries it is recommended that water is tested more frequently and can benefit from the ease of use and speedy results that HydroSense Pro Ultra DIY Legionella test kits can provide, including:

  • Hospitals and care homes

With complex water systems and caring for patients that have compromised immune systems, frequent water test is a must. These testing kits can lead to early detections and quick remedial action

  • Commercial Real Estate

Owners of commercial buildings with cooling towers/evaporative cooling systems or large water systems will find this new testing kit an invaluable product for early detection and prevention of the spread of Legionella Bacteria for the protection of public health

  • Manufacturing Plants

With manufacturing plants using complex and extensive water systems and cooling systems on site, early detection of Legionella, can aid in early remedial action and preventing outbreaks which can cause costly shutdowns, supply chain reputation and productivity,

How the Legionella Testing Kit Pro Works

If only a red line appears under C then neither Serogroup 1 nor Serogroup 2-15 has been detected

If there are red lines at pos.1 and at C then Serogroup 1 has been detected (≥ 100 CFU/L)

If a green line is present at pos.2 and a red line on the C position, Serogroups 2-15 have been detected. (≥100 CFU/L).

If there are lines present at pos.1, pos.2 and at the C point then Serogroups 1 & Serogroups 2-15 have been detected (≥100 CFU/L)